cms_NH: 67
Data source: Big Local News · About: big-local-datasette
rowid | facility_name | facility_id | address | city | state | zip | inspection_date | deficiency_tag | scope_severity | complaint | standard | eventid | inspection_text | filedate |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
67 | DOVER CENTER FOR HEALTH & REHABILITATION | 305018 | 307 PLAZA DRIVE | DOVER | NH | 3820 | 2018-04-13 | 690 | D | 0 | 1 | WGWA11 | **NOTE- TERMS IN BRACKETS HAVE BEEN EDITED TO PROTECT CONFIDENTIALITY** Based on observation, record review, and interview, the facility failed to ensure that a resident with an indwelling catheter was assessed for removal of the catheter as soon as possible unless the resident's clinical condition demonstrates that catheterization is necessary, for 1 of 2 residents reviewed for catheters in a sample of 22 residents (Resident identifier is #185). Findings include: Observation of Resident #185 on 4/11/18 at 8:36 am revealed the resident had a urinary catheter. Review of physician orders [REDACTED].#185 revealed an order dated 4/8/18 for catheter 16 French with 10 cc balloon to straight drainage. Review of Resident #185's list of [DIAGNOSES REDACTED]. Interview with Staff J (Licensed Practical Nurse) on 4/13/18 at 9:37 am revealed that Resident #185 had a catheter when admitted from the hospital on [DATE] and the reason for the catheter was patient request. Interview with Staff A (Director of Nursing) on 4/13/17 at approximately 1:30 am confirmed there was no clinical [DIAGNOSES REDACTED]. | 2020-09-01 |